DT 002

DT 002 Digital desk top station

Digital desktop station with 12 push-to-talk and 4 functional keys, numerical keypad with 12 keys. Display, interface to hanset 1 HAS 004, including 3 meters connection cable and wall socket.

Main features

  1. dialling to any station via numerical keys
  2. all keys for immediate connection with indi≠vidual labelling area
  3. call and busy signals by light emitting diodes
  4. noise compensated goose neck microphone with dynamic compression
  5. adjustment of microphone sensitivity and loudspeaker output
  6. unilaterally controlled communication with all stations of the system
  7. menu-driven operation via control keys
  8. connection via FCC68 socket

Mechanical data
dimensions (without microphone)........................................ 182 mm* 130mm*55mm
weigh.................................................................................... ca. 0,8 kg
dim. booster amplifier25 DVT 01......................................... 110mm* 189mm*70mm
weight including plastic housing........................................... ca. 0,7 kg

Electrical data intercom station
operating voltage range........................................................ 42 V - 72 V DC
quiescent & max. current consumption .............................. 10 mA, 100 mA
loudspeaker output power.................................................... 1 W
sound pressure level (distance 1 m)................................... 75 dB
frequency range................................................................... 300 3400 Hz
output level AF signal .......................................................... 0 dB
loudspeaker.......................................................................... 5 W / 8 Ohm

Environmental requirements and standards
ambient temperature ........................................................... 0 - 55∞ C
degree of protection............................................................. IP 40
EMC test (CE sign).............................................................. EN 50081-1, EN 50082-1